#ERROR MESSAGE CARRIER OUTDOOR IUNIT COMMUNICATION FAULT CODE#
Press CLR button to clear the existing fault code (controller displays 7F).Navigate through TIMER buttons until all LEDs flash, accompanied by the internal buzzer – compare the.More specific codes may be obtained, while in the fault mode through the wireless controller. Second when the system is initially powered.
#ERROR MESSAGE CARRIER OUTDOOR IUNIT COMMUNICATION FAULT HOW TO#
How to check Toshiba RAS “N” Series aircon error code?įault codes are displayed through the LEDs flashing at 5 times per second. Often appears as an E01 fault code E04 E04 Indoor unit (except twin slave) receives no communication from outdoor unit can include comprssorer klixon E08 E08 Duplicated indoor address E09 E09 2 local controller on a group – both configured as masters E10 E10 Indoor PCB failure E18 E18 Communication failure between master indoor unit and slave F01 F01 Indoor TCJ sensor error F02 F02 Indoor TC2 sensor error F04 F04 TD Sensor error F06 TE/TS Sensor error F06 TE Sensor error F07 TL Sensor Error F08 F08 TO sensor error F10 F10 Indoor TA sensor error F12 TS Sensor Error F13 Number of detected IPDU units is reduced F15 TE,TS Sensor Error IPDU error F23 PS sensor error F29 F29 Indoor PCB failure F31 Outdoor P.C EEPROM Error H01 H01 Inverter compressor over current detected H02 H02 Master outdoor unit over current detected shortly after start up (compressor lock) H03 H03 Current detected on master outdoor unit whilst idle H04 Case thermostat operation H06 H06 Low pressure detected by Ps sensor (0.02Mpa) L03 L03 Duplicated master indoor units in a group L07 L07 Indoor in a group previously addressed as a single unit – check addressing L08 L08 Indoor address not set L09 L09 Indoor unit capacity not set L10 Unset jumper of service P.C board L29 L29 IPDU error ( number of detected IPDU is reduced ) 元0 元0 Input on CN80 circuit for 1 minute 元1 元1 Outdoor PCB error P01 P01 Indoor fan motor error P03 P03 High discharge temperature (TD1 exceeded 115☌) P04 P04 High pressure switch activated (Detected by high TE temp on Digital Inverter) P05 Open Phase of 3 phase power supply P07 P07 Heat sink overheat Error P10 P10 Float switch activated P12 P12 Indoor fan motor error – detected by feedback circuit P15 TD.TS sensor Error P19 P19 Wrong change in temperature (4 way valve error) P20 TL Sensor error P22 P22 Outdoor fan IPDU error P26 P26 Short circuit error of compressor driving element P29 P29 Compressor error detected by feedback circuit P31 P31 Indoor PCB error Toshiba RAS “N” Series aircon error codes Also check that there is a master controller E02 E02 Local controller failure (unable to transmit) E03 E03 Master indoor unit receives no data to A-B.

3 series earlier 4 series onwards Possible causes E01 E01 Controller (local or network) receives no communication from a master indoor unit- could include that master is turned off.
#ERROR MESSAGE CARRIER OUTDOOR IUNIT COMMUNICATION FAULT FULL#
This guide we offer you the full list of Toshiba air conditioning fault codes that will help you. Searching for Toshiba air conditioner error codes to fix your Toshiba aircon issues?